For over 70 years, Metro Hydraulic Jack Company, a third-generation, family-owned and operated business, has been providing industrial hydraulic parts and equipment services to commercial, automotive, marine, refuse, and construction industries.
More About Our Company
10000 psi, 3/8" ports, 5 gpm max flow rate.
Application: Single acting cylinders.
Actuation: Solenoid operated, 230 volt, 50/60 Hz.
Functions: Cylinder piston advances when solenoid is de-energized and pump is running. When solenoid is energized, oil is directed to reservoir, and piston returns. For “hold” position, pump is stopped with solenoid de-energized.
Used on these pumps: PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
Valves above are shipped without control switch. Use 202777 remote hand switch.When this valve is mounted, the pump must be equipped with an outlet check valve.
Conversion kit 251528 must be used when mounting the valves on PA17 or PE17 pumps.
To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.
When ordering any valve for a PE30 or PG30 series pump, 1/2" longer mounting screws are required.For valves 9570 order four 10856 cap screws.
Application: Single acting cylinders.
Actuation: Solenoid operated, 230 volt, 50/60 Hz.
Functions: Cylinder piston advances when solenoid is de-energized and pump is running. When solenoid is energized, oil is directed to reservoir, and piston returns. For “hold” position, pump is stopped with solenoid de-energized.
Used on these pumps: PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
Valves above are shipped without control switch. Use 202777 remote hand switch.When this valve is mounted, the pump must be equipped with an outlet check valve.
Conversion kit 251528 must be used when mounting the valves on PA17 or PE17 pumps.
To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.
When ordering any valve for a PE30 or PG30 series pump, 1/2" longer mounting screws are required.For valves 9570 order four 10856 cap screws.
Unit of Measure
Valve Type |
N/A3 - Way, 2 Position |
Actuation |
N/ASolenoid operated |
Pressure Rating |
N/A10000 psi |
Max. Flow Rate |
N/A5 GPM |
Port Size |
N/A3/8 inches |
Function |
N/AAdvance/Hold Return |
Operation |
N/ASolenoid |
Application |
N/ASingle Acting Cylinder |
使用阿n Pumps |
N/APE17PE21PE30PE46PE55PE84PE90PE120PQ60PQ120PE200PE400 |
AC Voltage |
N/A230 V |
Power supply |
N/A230 volt, 50/60 Hz |
Weight |
N/A9.6 lbs. |
Ship Weight |
N/A10.2 lbs. |